Flash Canon Speedlite 550ex con funda original y pie.
Excelente estado. Está equipado con Zoom para cubrir de 17mm a 105mm. Funciones de segunda cortina, speed sync, estroboscópico, Master o Slave entre otras...
|
|
|
|
|
Precio: U$S 450
|
Especificaciones
|
 |
Compatible Cameras
|
E-TTL
operation with all EOS digital SLRs; PowerShot G2, G3, G5, G6, and
Pro1; and the following EOS film cameras - EOS-1v, EOS-3, Elan 7N
series, Elan 7 series, Elan II series, Rebel T2, Ti, K2, GII, G.
TTL operation with all other 35mm EOS SLRs, and Canon T90.
|
Guide Number
|
190 (at ISO 100, feet) / 58 (meters); flash head at 105mm zoom setting
|
Number of Flashes
|
Approx. 100 to 700, with fresh AA-size alkaline batteries
|
Recycling Time
|
Approx. 0.1 to 6 seconds, with fresh AA-size alkaline batteries
|
Flash Range
|
(At ISO 100, with 50mm f/1.4 lens at f/1.4) - Approx. 1.6 to 98.4 feet / 0.5 to 30m
|
AF Assist Beam
|
Built-in;
covers all focus points in EOS cameras with 1, 3, 5, 7, 9, or 45 AF
points; Distance range - 2 to 32.8 feet (0.6 to 10m) at center; 2 to
16.4 feet (0.6 to 5m) at periphery
|
Custom Functions
|
Fourteen Speedlite Custom Functions built-in; set on Speedlite's LCD panel |
Especificaciones completas
|
Specifications
|
 |
Type
|
Direct- sync, shoe-mount flash with E-TTL/TTL autoflash control and
wireless transmission/reception (E-TTL preflash, AF-assist beam, auto
zoom, and bounce flash).
|
Compatible Cameras
|
Type-A EOS cameras (for E-TTL autoflash control). Type-B EOS cameras (for TTL autoflash control).
|
Guide Number
|
Normal Mode (ISO 100)
|
Flash Coverage (mm)
|
17
|
24
|
28
|
35
|
50
|
70
|
80
|
105
|
|
Normal (full) Flash Guide No.
|
15
|
28
|
30
|
36
|
42
|
46
|
50
|
55
|
|
Quick Flash
|
Same as for manual flash from 1/2 to 1/16
|
|
Manual Flash Guide No.
|
1/1
|
m
feet
|
15
50
|
28
92
|
30
99
|
36
119
|
42
139
|
46
152
|
50
165
|
55
182
|
|
1/2
|
m
feet
|
10.6
35
|
19.8
65
|
21.2
70
|
25.5
84
|
29.7
98
|
32.5
107
|
35.4
117
|
39
128
|
|
1/4
|
m
feet
|
7.5
25
|
14
46
|
15
50
|
18
59
|
21
69
|
23
76
|
25
83
|
27.5
91
|
|
1/8
|
m
feet
|
5.3
18
|
9.9
33
|
10.6
35
|
12.7
42
|
14.8
49
|
16.3
54
|
17.7
58
|
19.5
64
|
|
1/16
|
m
feet
|
3.8
13
|
7
23
|
7.5
25
|
9
30
|
10.5
35
|
11.5
38
|
12.5
41
|
13.8
46
|
|
1/32
|
m
feet
|
2.7
9
|
4.9
16
|
5.3
18
|
6.4
21
|
7.4
24
|
8.1
27
|
8.8
29
|
9.7
32
|
|
1/64
|
m
feet
|
1.9
6.3
|
3.5
12
|
3.8
13
|
4.5
15
|
5.3
18
|
5.8
19
|
6.3
21
|
6.9
23
|
|
1/128
|
m
feet
|
1.4
4.6
|
2.5
8.3
|
2.7
8.9
|
3.2
11
|
3.7
12
|
4.1
14
|
4.4
15
|
4.9
16
|
High-Speed Sync (FP Flash, ISO 100)
|
Shutter Speed
|
Flash Coverage (mm)
|
|
17
|
24
|
28
|
35
|
50
|
70
|
80
|
105
|
|
1/125
|
m
ft |
10.6
35 |
19.8
65 |
21.2
70 |
25.2
83 |
29.7
98 |
32.5
107 |
35.4
117 |
38.9
128 |
|
1/160
|
m
ft |
9.4
31 |
17.5
58 |
18.8
62 |
22.5
74 |
26.3
87 |
28.8
95 |
31.3
103 |
34.4
114 |
|
1/180
|
m
ft |
8.8
29 |
16.5
55 |
17.7
58 |
21.2
70 |
24.7
82 |
27.1
90 |
29.5
97 |
32.4
107 |
|
1/250
|
m
ft |
7.5
25 |
14.0
46 |
15.0
50 |
18.0
59 |
21.0
69 |
23.0
76 |
25
83 |
27.5
25 |
|
1/320
|
m
ft |
6.6
22 |
12.4
41 |
13.3
44 |
15.9
53 |
18.6
61 |
20.3
67 |
22.1
73 |
24.3
80 |
|
1/350
|
m
ft |
6.3
21 |
11.8
39 |
12.7
42 |
15.2
50 |
17.7
58 |
19.4
64 |
21.1
70 |
23.2
77 |
|
1/400
|
m
ft |
5.9
20 |
11.1
37 |
11.9
39 |
14.2
47 |
16.6
55 |
18.2
60 |
19.8
65 |
21.7
72 |
|
1/500
|
m
ft |
5.3 >
> |
9.9
33 |
10.6
35 |
12.7
42 |
14.8
49 |
16.3
54 |
17.7
58 |
19.4
64 |
|
1/640
|
m
ft |
4.7
16 |
8.8
29 |
9.4
31 |
11.3
37 |
13.1
43 |
14.4
48 |
15.6
52 |
17.2
57 |
|
1/750
|
m
ft |
4.3
14 |
8.1
27 |
8.7
29 |
10.4
34 |
12.1
40 |
13.3
44 |
14.4
48 |
15.9
53 |
|
1/800
|
m
ft |
4.2
14 |
7.8
26 |
8.4
28 |
10.1
33 |
11.7
39 |
12.9
43 |
14
46 |
15.4
51 |
|
1/1000
|
m
ft |
3.8
13 |
7.0
23 |
7.5
25 |
9.0
30 |
10.5
35 |
11.5
38 |
12.5
41 |
13.8
46 |
|
1/1250
|
m
ft |
3.4
11 |
6.3
21 |
6.7
22 |
8.0
26 |
9.4
31 |
10.3
34 |
11.2
37 |
12.3
41 |
|
1/1500
|
m
ft |
3.1
10 |
5.7
19 |
6.1
20 |
7.3
24 |
8.6
28 |
9.4
31 |
10.2
34 |
11.2
37 |
|
1/1600
|
m
ft |
3.0
9.9 |
5.5
18 |
5.9
20 |
7.1
23 |
8.3
27 |
9.1
30 |
9.9
33 |
10.9
36 |
|
1/2000
|
m
ft |
2.7
9 |
4.9
16 |
5.3
18 |
6.4
21 |
7.4
24 |
8.1
27 |
8.8
29 |
9.7
32 |
|
1/2500
|
m
ft |
2.4
8 |
4.4
15 |
4.7
16 |
5.7
19 |
6.6
22 |
7.3
24 |
7.9
26 |
8.7
29 |
|
1/3000
|
m
ft |
2.2
7.3 |
4.0
13 |
4.3
14 |
5.2
17 |
6.1
20 |
6.6
22 |
7.2
24 |
7.9
26 |
|
1/3200
|
m
ft |
2.1
7 |
3.9
13 |
4.2
14 |
5.0
17 |
5.9
20 |
6.4
22 |
7
23 |
7.7
25 |
|
1/4000
|
m
ft |
1.9
6.3 |
3.5
12 |
3.8
13 |
4.5
15 |
5.3
18 |
5.8
19 |
6.3
21 |
6.9
23 |
|
1/5000
|
m
ft |
1.7
5.6 |
3.1
10 |
3.4
11 |
4.0
13 |
4.7
16 |
5.1
17 |
5.6
19 |
6.1
20 |
|
1/6000
|
m
ft |
1.5
5 |
2.9
9.6 |
3.1
10 |
3.7
12 |
4.3
14 |
4.7
16 |
5.1
17 |
5.6
19 |
|
1/6400
|
m
ft |
1.5
5 |
2.8
9.2 |
3.0
9.9 |
3.6
12 |
4.2
14 |
4.5
15 |
4.9
16 |
5.4
18 |
|
1/8000
|
m
ft
|
1.3
4.3 |
2.5
8.3
|
2.7
8.9
|
3.2
11
|
3.7
12 |
4.1
14 |
4.4
15 |
4.9
16 |
|
Flash Coverage
|
Auto zoom head covers 24mm, 28mm, 35mm, 50mm, 70mm, 80mm, and 105mm lens focal lengths automatically.
Manual zoom: Enabled with zoom button.
Wide panel: When the built-in wide panel covers the flash head, flash coverage is extended for 17mm lens local length.
|
Number of Flashes
|
|
Power Source
|
Available
Flashes
|
| Internal Only: |
4 x AA Alkaline
4 x AA Ni-Cd
|
100 - 700
40 - 300
|
| Transistor Pack E: |
Ni-Cd Pack TP
6 x C Alkaline
|
300 - 1800
350 - 2200
|
| Compact Battery Pack CP-E2: |
6 x AA Alkaline
6 x AA Ni-Cd
|
350 - 2200
130 - 900
|
|
Recycling Time
|
|
Power Source
|
Recharging Time (sec.)
|
|
Quick Flash
|
Normal Flash
|
| Internal Only: |
4 x AA Alkaline
4 x AA Ni-Cd
|
0.1 - 4
0.1 - 2.5
|
0.1 - 8
0.1 - 5
|
| Transistor Pack E: |
Ni-Cd Pack TP
6 x C Alkaline
|
0.1 - 1.5
0.1 - 2
|
0.1 - 3
0.1 - 5
|
| Compact Battery Pack CP-E2: |
6 x AA Alkaline
6 x AA Ni-Cd
|
0.1 - 1.5
0.1 - 1
|
0.1 - 5
0.1 - 2
|
|
Flash Duration
|
0.2 ms or less. For quick flash: 2.3 ms or shorter.
|
Sync Speed
|
According to camera.
|
Flash Range
|
With 50mm f/1.4 lens (at ISO 100):
With normal flash: 0.5-30 meters/ 1.6- 100 feet
With quick flash: Min. 0.5 - 7.5 meters and max. 0.5 - 21 meters/: Min. 1.6 - 25 feet and max. 1.6 - 70 feet
With high- speed sync: 0.5 - 15 meters/ 1.6 - 49 feet (at 1/250 sec.)
|
Flash Modes
|
Normal flash; Quick flash; High-speed sync (FP flash); Stroboscopic
flash: 41 flash frequency settings, 31 firing settings; Preflash:
Obtains exposure reading for E-TTL autoflash control; Test flash: With
test firing button; Modeling flash: Fired with the EOS-3's
depth-of-field preview button
|
Exposure Control Modes
|
E-TTL autoflash (with Type-A cameras)
TTL autoflash (with Type-B cameras)
|
Flash Metering System
|
1. E-TTL autoflash with instant metering using a preflash (with Type-A cameras).
2. E-TTL autoflash with instant partial metering using a preflash (with Type-A cameras).
3. E-TTL autoflash with instant spot metering using a preflash (with Type-A cameras).
4. TTL off-the-film autoflash metering (with Type-B cameras).
|
Flash Exposure Compensation
|
1. Automatic flash output reduction for fill flash.
2. Flash exposure compensation adjustable manually with the Speedlite up to +/-3 stops in 1/3- or 1/2- stop increments.
3. Flash exposure compensation adjustable manually up to ±3 stops in
1/3- or 1/2- stop increments with cameras equipped with flash exposure
compensation function.
|
Flash Exposure Bracketing
|
Set with the Speedlite up to +/-3 stops in 1/3-stop or 1/2-stop increments.
|
Flash Exposure Confirmation
|
Yellow-green pilot lamp lights.
|
Flash-ready Indication
|
Red pilot lamp indicates normal flash ready.
Green pilot lamp indicates quick flash ready.
|
AF Assist Beam
|
Linked to area AF (45 focusing points), effective from approx. 0.6 to
10 meters / 2 to 33 feet at the center and 0.6 to 5 meters / 2 to 16
feet along the periphery (in total darkness).
|
Bounce Positions
|
|
Direction
|
Angle
|
Click Stops
|
|
Up
|
0° - 90°
|
0°, 60°, 75°, 90°
|
|
Down
|
0° - 7°
|
0°, 7°
|
|
Left
|
0° - 180°
|
0°, 60°, 75°, 90°, 120°, 150°, 180°
|
|
Right
|
0° - 90°
|
0°, 60°, 75°, 90°
|
|
Custom Functions
|
|
Function
|
Custom Function No.
|
Setting
|
Description
|
|
FEB cancellation after completion
|
CF-1
|
0
|
Enabled
|
|
1
|
Disabled
|
|
FEB sequence
|
CF-2
|
0
|
Correct exposure, underexposure, overexposure
|
|
1
|
Underexposure, correct exposure, overexposure
|
|
Flash metering system
|
CF-3
|
0
|
E-TTL
|
|
1
|
TTL
|
|
Slave unit SE mode activation
|
CF-4
|
0
|
Activate after 60 min. of non- operation
|
|
1
|
Active after 10 min. of non- operation.
|
|
Slave unit SE mode cancellation
|
CF-5
|
0
|
Enable SE mode cancelleation by master unit for 1 hour.
|
|
1
|
Enable SE mode cancellation by master unit for 8 hours.
|
|
Modeling flash
|
CF-6
|
0
|
Enabled
|
|
1
|
Disabled
|
|
 |
Transmission System
|
Optical pulse transmission
|
Configuration
|
Camera, master unit, and slave unit(s)
|
Wireless Switchover
|
With wireless selector
|
Wireless Selector Positions
|
OFF, Master, Slave
|
Channels
|
4 (Master unit)
|
Transmission Angle
|
Horizontal: Approx. 80° / Vertical: Approx. 60° (At M 24 mm zoom
setting) (Manual zooming of flash head also enabled)
|
Transmission Range
|
Indoors: Approx. 12 to 15 meters / 39.3 to 49.2 feet Outdoors: Approx. 8 to 10 meters / 26.2 to 32.8 feet
|
Number of Transmissions
|
Approx. 1500 (without master unit firing)
|
Controllable Slaves
|
A, B, C (3 groups)
|
Flash Control
|
1. E- TTL autoflash (with Type-A cameras) High-speed sync (FP flash) /
FE lock / flash exposure compensation / FEB / flash ratio control
2. Manual flash (with Type A and B cameras)
3. Stroboscopic flash (with Type A and B cameras)
|
Flash Ratio Control
|
A:B = 8:1 to 1:1 or 1:1 to 1:8 (In thirteen 1/2-stop increments) (For
C, flash exposure compensation can be set up to +/-3 stops in 1/3 or
1/2-stop increments.)
|
Master Flash
|
ON/OFF possible (When ON, automatic set as slave unit A.) (Slave unit)
|
Reception Angle
|
Horizontal: Approx. 80°/ Vertical: Approx. 60°
|
Flash Coverage
|
Set automatically to M 24mm (Manual zooming of flash head also enabled)
|
Flash-ready Indication
|
AF-assist beam emitter blinks
|
Flash Modes
|
1. Controlled automatically by master unit
2. Manual flash and stroboscopic flash settable independently from master unit.
|
Flash Exposure Compensation
|
Settable individually with each slave unit up to +/-±3 stops in 1/3- or 1/2-stop increments.
|
Slave Operation Confirmation
|
Enabled with master unit's test firing button.
|
Slave Unit SE Mode Cancellation
|
While the slave unit's SE mode is in effect, the slave unit turns on
when a flash is fired. The slave unit's SE mode can be canceled by the
following wireless operations:
1. When the master unit's test firing button is pressed.
2. When the camera's FE lock button is pressed.
|
 |
Power Source
|
Size-AA alkaline LR6 batteries (6 V) x 4; Size-AA Nicad KR 15/51 batteries x 4 Size-AA Lithium FR6 batteries (6 V) x 4
|
External Power Source
|
Compact Battery Pack CP-E2 Size-AA alkaline LR6 (AM-3) batteries (9 V)
x 6; Transistor Pack E Battery Magazine TP with size-C alkaline LR14
(AM-2) batteries (9 V) x 6 Ni-Cd Pack TP (NR-SC Ni- Cd batteries x 6 in
sealed pack)
|
SE Mode
|
With the power switch set to SE, the Speedlite enters the SE mode as follows:
1. On-camera master unit enters the SE mode after 90 sec. of non-use.
2. Slave unit enters SE mode after 60 min. (or 10 min. with CF-4) of non-use.
|
Dimensions
|
80 (W) x 138 (H) x 112 (D) mm/ 3.1 (W) x 5.4 (H) x 4.4 (D) in
|
Weight
|
405g / 14.2 oz
|

|
|
|
|
|